AR# 10489

3.1i Spartan MAP - FATAL_ERROR:Ncd:basncsignal.c:249:1.15.22.1.2.1 -

Description

Keywords: basncsignal, 249, Could not find, bel, F1

Urgency: Standard

General Description:
A case has been seen where a Spartan design failed in MAP
with the fatal error:

"FATAL_ERROR:Ncd:basncsignal.c:249:1.15.22.1.2.1 - Could not find a bel for a
signal on pin F1 of comp c_clk_rec_pulse/n1204<0>. Its current programmed
state is : CLKX:CLK YMUX:G G3MUX:G3I G2MUX:G2I CARRY:FORCE XQMUX:QX DX:H
H1:C1 SR:C3 H:#LUT:H=(H1+G)*F H0:SR H2:F G:#LUT:G=(G3+G2)+G1 F:#LUT:F=F3
CINMUX:F3 SRX:RESET Process will terminate. To resolve this error, please
consult the Answers Database and other online resources at
http://support.xilinx.com"

NOTE: This answer record is only a potential match for your issue if the
architecture is 4K-based, and the pin mentioned is a CLB LUT input.

Solution

A basncsignal.c:249 error occurs when MAP recognizes that the external
pin connectivity of a component is not consistent with the internal configuration.
In this case, there is an external signal on pin F1; but internally, the F-LUT is
configured to use only pin F3.

Errors of this type can often be avoided by altering the way that a component
is being packed into a CLB. In this case, isolating the FMAP component
involved with an XBLKNM MAP constraint resolves the problem.

A workaround is to apply the UCF constraint:

INST U2367_map XBLKNM = XLNX_WA ;

This problem is scheduled to be fixed in the next major release
following 3.1i. This release is currently scheduled for July, 2001.