AR# 11061

3.x FPGA Express - FPGA Express ignores LOC attributes on 3-state IOBs

Description

Keywords: FPGA Express, 3-state, tri-state, tri, I/O, LOC, constraint, attribute

Urgency: Standard

General Description:
FPGA Express ignores LOC attributes in CPLDs if the IOB is configured as a 3-state I/O. If the I/O is configured as an input or an output, the LOC attribute will be written to the netlist; however, a LOC attribute for a 3-state I/O will be ignored and is not written into the netlist.

Solution

To work around this issue, write the LOC constraints into the UCF file.