AR# 11131

5.1i TRCE (Trace), Virtex-II - Trace and SPEEDPRINT for Virtex-II fail when prorating voltage

Description

General Description:

When I try to run either Trace or SPEEDPRINT with a voltage specification, the following messages are reported:

- "Requested a Voltage of <> Volts"

- "Requested voltage (<>) outside supported range (1.60 to 2.00)"

This happens even if the default voltage of 1.5 is specified.

Solution

Voltage prorating is not yet supported for Virtex-II. Users should not specify any voltage; the given values will correspond to the default core voltage of 1.5V.

AR# 11131
Date Created 08/29/2007
Last Updated 01/18/2010
Status Archive