AR# 11570

HDL Bencher - How do I obtain a simulation with valid outputs from a waveform with uninitialized inputs?

Description

Keywords: Project, Navigator, HDL, Bencher, initialize, inputs, simulation

Urgency: Standard

General Description:
How do I obtain a simulation with valid outputs from a waveform with uninitialized inputs?

Solution

In version 2.0, HDL Bencher no longer asks if you would like to initialize all inputs to a known state. Therefore, you must take the following steps to ensure valid outputs in simulation:

1. In Project Navigator, set the simulation run time to 0 ns.

2. In the simulator, force the uninitialized input ports (i.e., GSR or GTS) manually to some known value (such as 0 or 1).

3. Run the testbench.
AR# 11570
Date Created 05/09/2001
Last Updated 12/11/2006