AR #13229 - 11.1 Timing - I need a positive hold value, but I get a hold violation on my input port

All Recent Answers

Search Answers Database


 

11.1 Timing - I need a positive hold value, but I get a hold violation on my input port

AR# 13229
Topic SW-Timing Analyzer/TRCE
Last Modified 2009-07-07 00:00:00.0
Status Active

Description

Keywords: TRCE, positive, hold, value, input, port

I need a positive hold requirement for my input port, but the timing tools are reporting a hold violation. Why am I receiving a hold violation, and how can I solve this issue?

Solution

If you have positive hold time requirements and you do not specify a data VALID duration with your OFFSET constraints, you will receive a hold error (TRCE assumes VALID=OFFSET for a zero hold time check).

For more details on timing constraints, please see the Timing Constraints User Guide: http://www.xilinx.com/support/documentation/sw_manuals/xilinx11/ug612.pdf
 
 