AR# 13504

7.1i NGDBuild - "WARNING:NgdBuild:707 - The length of the binary value for the attribute 'xxx' on instance 'xxx' should be 11 bits long..."


Keywords: GT, properties, attributes, 4.1i, 5.1i, 6.1i, 7.1i

When NGDBuild is performing Logical DRC, if any of the Gigabit Transceiver properties use a prefix on the binary or hexadecimal properties, (i.e., setting CLK_COR_SEQ_1_4 to 11'b00010110101), NGDBuild reports the following warning:

"WARNING:NgdBuild:707 - The length of the binary value for the attribute CLK_COR_SEQ_1_4 on instance GT_FIBRE_CHAN_1_inst should be 11 bits long. The current value set is only 15 long."


This is a false warning, and you can safely ignore it.