AR #15720 - 5.1i CPLD Hprep6 CoolRunner-II - VREF I/O Standards (HSTL-1, SSTL2-1, SSTL 3-1) are not working on the device

Search Answers Database


 

5.1i CPLD Hprep6 CoolRunner-II - VREF I/O Standards (HSTL-1, SSTL2-1, SSTL 3-1) are not working on the device

AR# 15720
Part hprep6
Last Modified 2002-12-09 00:00:00.0
Status Active
Keywords 5.1i, CPLD, Hprep6, CoolRunner-II, VREF, HSTL-1, SSTL2-1, SSTL 3-1, termination

Description

Keywords: 5.1i, CPLD, Hprep6, CoolRunner-II, VREF, HSTL-1, SSTL2-1, SSTL 3-1, termination

Urgency: Standard

General Description:
When I implement an I/O Standard that requires a VREF (HSTL-1, SSTL2-1, SSTL 3-1), the inputs do not function correctly on the device.

Solution

This problem is due to bug that occurs when the VREF pins are being terminated internally (either with bus-hold or with a weak pull-up).

This problem is fixed in the latest 5.1i Service Pack, available at:
http://support.xilinx.com/support/techsup/sw_updates
The first service pack containing the fix is 5.1i Service Pack 3.
 
 