3.1.1 EDK - Error: "Version 1.00.b of IP type opb_v20 not found; Instance myopb of type opb_v20 is excluded from design"

Description

Keywords: EDK, opb_v20, opb, 3.1

Urgency: Standard

General Description:
After I install Service Pack 1 for EDK 3.1, the following error is reported:

"Version 1.00.b of IP type opb_v20 not found.
Instance myopb of type opb_v20 is excluded from design."

Solution

In EDK 3.1 Service Pack 1, version 1.00.b of the OPB has been made obsolete. You must upgrade your system hardware to version 1.10.a of the OPB.

Change the HW_VER PARAMETER in the MHS instantiation from:

BEGIN opb_v20
PARAMETER INSTANCE = myopb
PARAMETER HW_VER = 1.00.b
PORT OPB_Clk = sys_clk
PORT SYS_Rst = sys_rst
END

to:

BEGIN opb_v20
PARAMETER INSTANCE = myopb
PARAMETER HW_VER = 1.10.a
PORT OPB_Clk = sys_clk
PORT SYS_Rst = sys_rst
END