UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 1603

CPLD XC9500/XL/XV - When can the XC9500 internal IOB pull-up be accessed?

Description

General Description:

How do I use the pull-up in the IOB for XC9500/XL/XV devices?

Solution

In the XC9500/XL/XV IOBs, an internal pull-up becomes active during power-up, device configuration, and Intest only.

- For active I/O, these pull-ups cannot be accessed or activated during normal operation.

- For unused I/O, please see (Xilinx Solution 1536)

AR# 1603
Date Created 08/21/2007
Last Updated 12/15/2012
Status Active
Type General Article