AR# 16207

5.1i Floorplanner - The hierarchy window's display is incorrect, or multiple RPM components are merged to overload one RPM


Keywords: Floorplanner, RPM, hierarchy, display, components

Urgency: Standard

General Description:
The presence of multiple instantiated modules can cause Floorplanner's hierarchy window to display information incorrectly or to merge components from all RPMs into one RPM.


This problem is caused by RPMs that include a HU_SET constraint. To work around this issue, use a U_SET or H_SET constraint if possible. (Only Floorplanner GUIs should be affected by this issue.)

This problem is fixed in the latest 5.2i Service Pack available at:
The first service pack containing the fix is 5.2i Service Pack 1.
AR# 16207
Date Created 11/21/2002
Last Updated 03/06/2005
Status Archive
Type General Article