| AR# | 16270 |
| Part | Timing Analyzer |
| Last Modified | 2005-03-07 00:00:00.0 |
| Status | Archive |
| Keywords | TRCE, Trace, Timing, errors, zero, constraint, met |
Keywords: TRCE, Trace, Timing, errors, zero, constraint, met
Urgency: Standard
General Description:
When I run a design through Timing Analyzer, the summary of the constraint says that no timing errors were detected. However, the minimum time listed for the constraint is more than what I requested.
For example:
Timing constraint: TS_clk = PERIOD TIMEGRP "clk" 30 nS HIGH 50.000000 % ;
"414065 items analyzed, 0 timing errors detected.
Minimum period is 33.286ns."