AR# 17759

6.1i SP2 Partial Reconfiguration - PAR fails after Phase 1.1 when bus macros are used in partial reconfiguration

Description

Urgency: Hot 

 

General Description: 

When I attempt to run PAR on a partial reconfiguration design using bus macros, PAR fails after Phase 1.1 and reports no information about the cause of the problem.

Solution

Due to bus macro compatibility issues with the ISE 6.1i constraints system, module-based partial reconfiguration is supported in ISE 6.1i with Service Pack 2 and later. 

 

The latest 6.1i Service Pack is available at: 

http://support.xilinx.com/xlnx/xil_sw_updates_home.jsp
The first service pack containing the fix is 6.1i Service Pack 2.

AR# 17759
Date Created 09/03/2007
Last Updated 05/15/2014
Status Archive