UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 17851

6.3i/6.2i/6.1i XST- "Warning:Xst:1605 - Primary port name 'port_name' not found for this constraint"

Description

Keywords: 1415, XCF, I/O, bidi, bidirectional, IOBUF

When I use the ".xcf" constraints file and specify an OFFSET IN constraint on a bidirectional port, the following warnings occur:

"WARNING:Xst:1605 - Primary port name 'port_name' not found for this constraint."
"WARNING:Xst:1415 - No path found for this constraint."

Solution

XST incorrectly processes a bidirectional port as an output port only when considering OFFSET constraints. Consequently, an OFFSET OUT constraint passes without warnings, but an OFFSET IN constraint generates the warnings listed above. To work around this issue, turn on write_timing_constraints as follows:

1. Right-click the "Synthesize - XST" process.
2. Select "Properties...".
3. In the "Synthesis Options' tab, select "Write Timing Constraints".

NOTE: However, enabling the "Write Timing Constraints" switch does not cause the warnings to disappear. Instead, the timing constraint is propagated to the ".ngc" file.

This issue has been fixed in ISE 7.1i
AR# 17851
Date Created 09/03/2007
Last Updated 01/06/2009
Status Archive