We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 17869

7.1i Timing Analyzer - Filter Paths by net "include only" is not working


General Description:

When I select "include only" on four nets, known to be constrained by an associated constraint that was analyzed, Timing Analyzer reports that zero items were analyzed. These nets are constrained under a constraint and should be analyzed. Why are they not "included"?


The four nets tagged as "included" nets should produce the correct path in question, but Timing Analyzer "ands" all of the nets and searches for a path that contains all of the nets. This is why Timing Analyzer returns zero items analyzed. You can work around this issue, by creating separate reports with individual nets in each report.

AR# 17869
Date Created 09/03/2007
Last Updated 01/18/2010
Status Archive
Type General Article