6.1i COREGen - Generating a core for a Mentor schematic design gives "ERROR: Selected Flow Vendor and Bus format are in conflict. Core <Selected Core> will not be elaborated."

Description

Keywords: Core, Mentor, Design Architect, Schematic, Symbol, Macro, Generate, elaborated, BusFormat, FlowVendor, BusFormatSquareBracketNotRipped, compatible

Urgency: Standard

General Description:
When Schematic and Mentor Graphics (Schematic) is selected in Project Options, the following error message appears in the transcript window.

"ERROR: Selected Flow Vendor and Bus format are in conflict. Core <Selected Core> will not be elaborated."

Also, an Elaboration Error pop-up window displays "Not all output products were generated successfully. View Messages."
Selecting 'Yes' in this window yields a more detailed message window with the following transcript:

"Preparing to elaborate core...
Warning: FlowVendor choice MentorSchematic is not compatible with selected bus format BusFormatSquareBracketNotRipped.
Error: Selected FlowVendor and BusFormat are in conflict. Core <Selected Core> will not be elaborated."

Solution

This error occurs if the Design Entry project options are set to Schematic and Mentor Graphics (Schematic). The bus format will automatically be set to B[I].

Select Project -> Project Options, and change the Design Entry Vendor from "Mentor Graphics (Schematic)" to "Other". This will allow a user to select any Netlist Bus Format.

Click OK to close the Project Options window and then generate the desired Core.