UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 19075

6.2 EDK, REVUP - Errors generated when opening ML300 Design 5 "No name (IO_IF) specified"

Description

Keywords: ML300, EDK, Design 5, PPC, MPD

Urgency: Standard

General Description:
When opening the ML300 Design 5 using EDK 6.2, the following errors occur:
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:24 No name (IO_IF) specified"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:25 No name (IO_IF) specified"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:158 - No IO_INTERFACE cpudbg_0 found as specified for PORT C405JTGTDO"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:163 - No IO_INTERFACE cpudbg_0 found as specified for PORT JTGC405TCK"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:164 - No IO_INTERFACE cpudbg_0 found as specified for PORT JTGC405TDI"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:165 - No IO_INTERFACE cpudbg_0 found as specified for PORT JTGC405TMS"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:166 - No IO_INTERFACE cpudbg_0 found as specified for PORT JTGC405TRSTNEG"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:172 - No IO_INTERFACE cpudbg_0 found as specified for PORT DBGC405DEBUGHALT"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:175 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCCYCLE"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:176 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCEVENEXECUTIONSTATUS"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:177 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCODDEXECUTIONSTATUS"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:178 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCTRACESTATUS"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:179 - No IO_INTERFACE trace_0 found as specified for PORT C405TRCTRIGGEREVENTOUT"
"ERROR:MDT - H:\xroads\testing_examples_62\ML300\design_5\projects\ml300_edk2\pcores\ppc405_v2_00_b\data\ppc405_v2_1_0.mpd:182 - No IO_INTERFACE trace_0 found as specified for PORT TRCC405TRIGGEREVENTIN"

Solution

In the ML300 Design 5, the PPC405 core is a pcore. The ppc405_v2_1_0.mpd file associated with this pcore includes invalid syntax. To resolve this issue, perform the following steps:
1. Remove the ppc405_v2_00_b pcore directory.
2. Close the project.
3. Re-open the project.