CPLD CoolRunner-II - What input voltage can induce latch-up?


Keywords: latchup, latch, up

High voltage spikes (above the Vin maximum listed in the data sheet) can cause the device inputs to latch-up. What is the value that needs to be exceeded for this to occur?


If the input voltage exceeds 8 Volts the input can latch-up.

It is not recommended to exceed the Vin maximum limits specified in the data sheet, as this will damage the I/O buffer over time.