AR# 19854 6.3i SimPrim, Timing Simulation - When I load the SDF for an X_EMAC, multiple errors report: "Instance '/uut/emacs' does not have a generic named 'thold_...". (VHDL, SDF)

Keywords: SimPrim, VHDL, timing, simulation, ModelSim, NC-VHDL, generic, thold_tieemac0configvec_phyemac0rxclk_negedge_posedge, X_EMAC, Virtex-4, SDF

Urgency: Standard

General Description:
When I load the SDF for an X_EMAC, the following errors occur:

"Error: emac_vhd_map_vhdl.sdf(14812): Instance '/uut/emacs' does not have a generic named 'thold_tieemac0configvec_phyemac0rxclk_negedge_posedge'.
Error: emac_vhd_map_vhdl.sdf(14811): Instance '/uut/emacs' does not have a generic named 'thold_tieemac0configvec_phyemac0rxclk_posedge_posedge'.
Error: emac_vhd_map_vhdl.sdf(14804): Instance '/uut/emacs' does not have a generic named 'thold_tieemac1configvec_phyemac1rxclk_negedge_posedge'.
Error: emac_vhd_map_vhdl.sdf(14803): Instance '/uut/emacs' does not have a generic named 'thold_tieemac1configvec_phyemac1rxclk_posedge_posedge'.
Error: emac_vhd_map_vhdl.sdf(14777): Instance '/uut/emacs' does not have a generic named 'tpd_clientemac0txgmiimiiclkin_emac0clientaninterrupt'.
Error: emac_vhd_map_vhdl.sdf(14812): Instance '/uut/emacs' does not have a generic named 'tsetup_tieemac0configvec_phyemac0rxclk_negedge_posedge'.
Error: emac_vhd_map_vhdl.sdf(14811): Instance '/uut/emacs' does not have a generic named 'tsetup_tieemac0configvec_phyemac0rxclk_posedge_posedge'.
Error: emac_vhd_map_vhdl.sdf(14804): Instance '/uut/emacs' does not have a generic named 'tsetup_tieemac1configvec_phyemac1rxclk_negedge_posedge'.
Error: emac_vhd_map_vhdl.sdf(14803): Instance '/uut/emacs' does not have a generic named 'tsetup_tieemac1configvec_phyemac1rxclk_posedge_posedge'."

This problem has been fixed in the latest 6.3i Service Pack available at:
http://support.xilinx.com/xlnx/xil_sw_updates_home.jsp
The first service pack containing the fix is 6.3i Service Pack 1.
AR# 19854
Date Created 09/03/2007
Last Updated 11/18/2008