AR# 20114

6.3 EDK, opb_iic v1.01.c - Setting the parameter C_GPO_WIDTH to 0 generates "ERROR:MDT <> PARAMETER C_GPO_WIDTH has value 0 which does not fall ..."

Description

General Description: 

I use the opb_iic core in my EDK design. PlatGen generates the error below when I set the parameter C_GPO_WIDTH to 0:  

 

'ERROR:MDT - H:\Case\Case_551217\system.mhs:42 - PARAMETER C_GPO_WIDTH has value 0 which does not fall in the range (1:8), specified in MPD"

Solution

To solve this problem, you can edit the file "C:\EDK\hw\XilinxProcessorIPLib\pcores\opb_iic_v1_01_c\data\opb_iic_v2_1_0.mpd". 

 

The incorrect line: 

PARAMETER C_GPO_WIDTH = 1, DT = INTEGER, RANGE = (1:8),  

 

The correct line is:  

PARAMETER C_GPO_WIDTH = 1, DT = INTEGER, RANGE = (0:8),