AR# 20535

EDK 6.3 - In opb2plb_bridge_v1_00_c, write immediately after read fails


General Description: 

In testing the opb2plb_bridge_v1_00_c, when an opb master tries to perform a write operation immediately after a read operation, the write gets converted to a read operation. One clock cycle delay between the operations fixes the problem.


This problem is fixed in the latest 6.3 EDK Service Pack, available at: 

The first service pack containing the fix is EDK 6.3 Service Pack 2.