UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 20597

System ACE CF-The System ACE error led is permanently on, and rev0 is not included in the file structure

Description

Keyword: configuration, revision

The System ACE error led is permanently on, and the JTAG chain will not configure. This can occur if the compact flash files structure does not start at rev0 and other revisions are being used.

Solution

The compact flash file system must have contiguous addressing in each collection. The first revision should be at the address cfgaddr0, the second at cfgaddr1, etc.

In iMPACT, you must select contiguous revisions starting at rev0 for each collection.

AR# 20597
Date Created 09/04/2007
Last Updated 12/15/2012
Status Active
Type General Article