When I use a DCM in an embedded design, the following warning appears:

"Performing System level DRCs on properties...
WARNING:MDT - Peripheral dcm_0 is not connected to any of the processors in the
system. Check for the following reasons.
1. dcm_0 is not connected to any of the buses connected to a processor.
2. dcm_0 does not have adresses set correctly.
3. dcm_0's address is not within any of the bridge windows connected to a
processor."

Solution

This warning can be safely ignored. There is an improper specification (IPTYPE=PERIPHERAL, rather than IPTYPE=IP) in the DCM's MPD file. This issue has been resolved in the next major release.