Virtex-E/-II/-II Pro/-4/-5 - What state is CCLK in after configuration is finished?


Keyword: CCLK, state, after configuration

What occurs to CCLK when the device is in Master mode and finished the start-up sequence?


The start-up sequence contains an End of Start-Up (EOS) signal that is released on the 8th state of the start-up sequence. If the device is in master mode, the CCLK will stop providing clocks when this signal is released and CCLK will be tied high with a weak internal pullup.