UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 22736

8.1i MAP - "FATAL_ERROR:Pack:pkibaexception.c:195:1.4 - Failed to program a device usage model for comp "MY_DCM"."

Description

When I run MAP, the following Fatal Error occurs: 

 

"FATAL_ERROR:Pack:pkibaexception.c:195:1.4 - Failed to program a device usage model for comp "DCM_AUTOCALIBRATION_dcm310/DCM_ADV/dcm310/DCM_ADV". The comp 

is an instance of type DCM_ADV. The following configuration string was used to program the device usage model: RSTINV:RST PSINCDECINV:PSINCDEC PSENINV:PSEN CLK_FEEDBACK:1X CLKDV_DIVIDE:2.0 CLKFX_DIVIDE:2 CLKFX_MULTIPLY:2 CLKIN_DIVIDE_BY_2:FALSE CLKOUT_PHASE_SHIFT:FIXED DCM_PERFORMANCE_MODE:MAX_SPEED DESKEW_ADJUST:SYSTEM_SYNCHRONOUS DFS_FREQUENCY_MODE:HIGH DLL_FREQUENCY_MODE:HIGH DUTY_CYCLE_CORRECTION:TRUE STARTUP_WAIT:FALSE BGM_MODE:BG_SNAPSHOT BGM_DIVIDE:16 BGM_MULTIPLY:16 BGM_CONFIG_REF_SEL:CLKIN BGM_VADJ:5 BGM_SAMPLE_LEN:2 BGM_VSDLY:0 BGM_SDLY:3 BGM_LDLY:5 BGM_VLDLY:7 DCM_EXT_FB_EN:FALSE DCM_UNUSED_TAPS_POWERDOWN:TRUE DCM_VREF_SOURCE:VBG_DLL DCM_VREG_ENABLE:TRUE DCM_CLKDV_CLKFX_ALIGNMENT:TRUE DCM_LOCK_HIGH:FALSE DFS_EARLY_LOCK:FALSE DFS_AVE_FREQ_ADJ_INTERVAL:3 DFS_AVE_FREQ_GAIN:2.0 DFS_AVE_FREQ_SAMPLE_INTERVAL:2 DFS_EXTEND_HALT_TIME:FALSE DFS_EXTEND_RUN_TIME:FALSE 

DFS_EXTEND_FLUSH_TIME:FALSE DFS_NON_STOP:FALSE DFS_SKIP_FINE:FALSE DFS_OSCILLATOR_MODE:PHASE_FREQ_LOCK DFS_COARSE_SEL:LEGACY DFS_FINE_SEL:LEGACY DFS_TP_SEL:LEVEL DFS_TRACKMODE:1 DFS_EN_RELRST:TRUE DLL_DESKEW_LOCK_BY1:FALSE DLL_PERIOD_LOCK_BY1:FALSE DLL_CONTROL_CLOCK_SPEED:HALF DLL_PHASE_DETECTOR_AUTO_RESET:TRUE DLL_PHASE_DETECTOR_MODE:ENHANCED DLL_PHASE_SHIFT_CALIBRATION:AUTO_DPS DLL_PHASE_SHIFT_LOCK_BY1:FALSE DLL_PD_DLY_SEL:0 DLL_CTL_SEL_CLKIN_DIV2:FALSE PMCD_SYNC:FALSE Exception 

text: MRBCF DCM_ADV Failure: INVALID_MODERB: "DESKEW_ADJUST" CFG: "RSTINV:RST PSINCDECINV:PSINCDEC PSENINV:PSEN CLK_FEEDBACK:1X CLKDV_DIVIDE:2.0 

CLKFX_DIVIDE:2 CLKFX_MULTIPLY:2 CLKIN_DIVIDE_BY_2:FALSE CLKOUT_PHASE_SHIFT:FIXED DCM_PERFORMANCE_MODE:MAX_SPEED DESKEW_ADJUST:SYSTEM_SYNCHRONOUS DFS_FREQUENCY_MODE:HIGH DLL_FREQUENCY_MODE:HIGH DUTY_CYCLE_CORRECTION:TRUE STARTUP_WAIT:FALSE 

BGM_MODE:BG_SNAPSHOT BGM_DIVIDE:16 BGM_MULTIPLY:16 BGM_CONFIG_REF_SEL:CLKIN BGM_VADJ:5 BGM_SAMPLE_LEN:2 BGM_VSDLY:0 BGM_SDLY:3 BGM_LDLY:5 BGM_VLDLY:7 DCM_EXT_FB_EN:FALSE DCM_UNUSED_TAPS_POWERDOWN:TRUE DCM_VREF_SOURCE:VBG_DLL DCM_VREG_ENABLE:TRUE DCM_CLKDV_CLKFX_ALIGNMENT:TRUE DCM_LOCK_HIGH:FALSE DFS_EARLY_LOCK:FALSE DFS_AVE_FREQ_ADJ_INTERVAL:3 DFS_AVE_FREQ_GAIN:2.0 

DFS_AVE_FREQ_SAMPLE_INTERVAL:2 DFS_EXTEND_HALT_TIME:FALSE DFS_EXTEND_RUN_TIME:FALSE DFS_EXTEND_FLUSH_TIME:FALSE DFS_NON_STOP:FALSE 

DFS_SKIP_FINE:FALSE DFS_OSCILLATOR_MODE:PHASE_FREQ_LOCK DFS_COARSE_SEL:LEGACY DFS_FINE_SEL:LEGACY DFS_TP_SEL:LEVEL DFS_TRACKMODE:1 DFS_EN_RELRST:TRUE DLL_DESKEW_LOCK_BY1:FALSE DLL_PERIOD_LOCK_BY1:FALSE DLL_CONTROL_CLOCK_SPEED:HALF DLL_PHASE_DETECTOR_AUTO_RESET:TRUE DLL_PHASE_DETECTOR_MODE:ENHANCED DLL_PHASE_SHIFT_CALIBRATION:AUTO_DPS DLL_PHASE_SHIFT_LOCK_BY1:FALSE DLL_PD_DLY_SEL:0 DLL_CTL_SEL_CLKIN_DIV2:FALSE PMCD_SYNC:FALSE " Process will terminate. To resolve this error, please consult the Answers Database and other online resources at http://support.xilinx.com. If you need further assistance, please open a Webcase by clicking on the "WebCase" link at http://support.xilinx.com"
 

How can I solve this problem?

Solution

This error can occur when your DESKEW_ADJUST value is lower case.  

 

This issue is scheduled to be fixed in the 8.2i release, which is scheduled for May, 2006. 

 

In the meantime, you can work around the error by changing the value to upper case. For example, change system_synchronous to SYSTEM_SYNCHRONOUS.

AR# 22736
Date Created 09/04/2007
Last Updated 05/19/2014
Status Archive
Type General Article