AR# 23814

8.2 System Generator for DSP - Why do I receive an error when the "Specify explicit sample period" option is selected and the "Provide enable port" or "Provide synchronous reset port" are not selected, on my Direct Digital Synthesis (DDS) v5.0 block?

Description

Why do I receive an error when the "Specify explicit sample period" option is selected and the "Provide enable port" or "Provide synchronous reset port" are not selected, on my Direct Digital Synthesis (DDS) v5.0 block?

Steps to reproduce:

1. Uncheck "Provide enable port" or "Provide synchronous reset port" checkbox.

(The "Specify explicit sample period" checkbox gets disabled but the "explicit sample period" field does not.)

2. If the value in this field is not equal to the Simulink period, you receive the following error when compiling the design:

Error Message:

Illegal Period. This blocks attempts to set period that is a non-integer multiple of the system rate.

Solution

This is a known problem that will be fixed in System Generator for DSP 9.1.

To work around the problem, do the following:

1. Uncheck the "Specify explicit sample period" checkbox.

2. Uncheck the "Provide enable port" or "Provide synchronous reset port" checkbox.