We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 24481

9.1i ISE - Timing constraint names are not displayed in the HTML timing report opened in Project Navigator


Keywords: analyzer, XML, display, link, TA, edit, trce, TRACE

Timing Analyzer does not display the constraint names in the HTML timing report as hyperlinks. Consequently, the report cannot be used with the Edit Source Constraint command.


The XML timing report does not contain UCF constraint names because Project Navigator is running TRACE without the -ucf switch. Since the XML timing report does not contain UCF constraint names, Timing Analyzer cannot display the names for linking.

This problem has been fixed in the latest 9.1i Service Pack available at:
The first service pack containing the fix is 9.1i Service Pack 1.
AR# 24481
Date Created 09/04/2007
Last Updated 04/17/2009
Status Archive
Type General Article