LogiCORE RapidIO v3.1 Rev 2 - duplicated packet can be seen upon RETRY

AR# 24527

Search For Another Answer

Topic Coregen RapidIO
Last Updated 01/09/2007
Status Active
Description

Keywords: v3.1, ip1_i, serial, parallel, high, speed, high-speed, PHY, logical, design environment, rio, srio, rapidio, discontinue, dsc, retry, duplicated, packets

When the buffer asserts discontinue (lnk_rdst_dsc_n) signal back to the PHY Rx a cycle before or in the same cycle as an embedded control symbol, the PHY will not properly discontinue the current packet. This will cause the packet to be duplicated upon Retry.

Solution

This issue will be fixed in Serial RapidIO v4.1 release expected to be available in February 2007.

If you need a fix for this issue sooner, please contact Xilinx Technical Support at:
www.xilinx.com
or
http://www.xilinx.com/support/techsup/tappinfo.htm

Please provide three XCO files from v3.1 core.

 
 