Main

11.3 System Generator for DSP - I cannot access the quantization parameters in the FDATool in System Generator. Why?

AR# 24616

Search For Another Answer

Topic SW-SysGen
Last Updated 09/10/2009
Status Active
Description

Keywords: FDATool, Quantization, FDA Tool, SysGen

The MATLAB FDATool has a button that allows you to set Quantization Parameters for your filter. This is useful for determining how many bits are needed in coefficient storage. However, when I open the FDATool from the Xilinx Blockset, this feature is not available.

Solution

The Xilinx FDATool uses the Simulink FDATool, as opposed to the MATLAB FDATool (type FDATool at the MATLAB command prompt). The Simulink FDATool does not contain this feature.

If you want to use this feature of the FDATool, you should invoke it from MATLAB instead of Simulink. You can then store the coefficients to a variable that can be used in your Simulink System Generator model.
 
 
/csi/footer.htm