Virtex-5 - Can I use LVDS outputs on Global Clock and Clock Capable I/O pins?

Description

In Virtex-4 devices, the ability to use LVDS outputs on global clock and clock capable I/O pins was removed, does the same restriction apply to Virtex-5?

Solution

No, this restriction does not exist in Virtex-5 devices. The GC and CC pins in a Virtex-5 device can be configured for any Virtex-5 supported I/O standard (both as inputs and outputs).