AR# 24765

BSDL Files - Devices xc2c32a and xc2c64a in 1532 mode are updated in 9.1.02

Description

When using the 1532 flow on the xc2c32a and xc2c64a devices, the following error occurs in iMPACT:

"Boundary-scan chain validated successfully.

'1': Performing Action : PROGRAM...

INFO:iMPACT:1045 - '1': Performing procedure: PROC_VERIFY_IDCODE...

INFO:iMPACT:1045 - '1': Performing flow: FLOW_VERIFY_IDCODE...

ERROR:iMPACT:1041 - Operation terminated.

Expected Data 00000110110000011000000010010011.

Read back Data 00000110111000011001000010010011.

Mask Data 00001111111111111000111111111111.

ERROR:iMPACT:1046 - Error, operation did not complete successfully. Action: PROGRAM, Procedure: PROC_VERIFY_IDCODE, flow : FLOW_VERIFY_IDCODE.

Elapsed time = 0 sec. "

Solution

This problem has been fixed in the latest 9.1i Service Pack available at:

http://www.xilinx.com/xlnx/xil_sw_updates_home.jsp
The first service pack containing the fix is 9.1i Service Pack 2.

AR# 24765
Date Created 09/04/2007
Last Updated 12/15/2012
Status Active
Type General Article