AR# 24882

8.2i EDK - ML505 BSB design results in an error when runing Platgen

Description

I downloaded the XBD file for the ML505 board from the web and created a design with external memory using the BSB, but when I run the design I receive the following error in Platgen:

"Error Message:

---------------------------------------

Check port drivers...

ERROR:MDT - sys_clk_s (OPB_Clk) - D:\MyData\DESIGNS\V5ML505\testboard\system.mhs

line 81 - connection has no driver!

ERROR:MDT - sys_clk_s (LMB_Clk) - D:\MyData\DESIGNS\V5ML505\testboard\system.mhs

line 106 - connection has no driver!

ERROR:MDT - sys_clk_s (LMB_Clk) - D:\MyData\DESIGNS\V5ML505\testboard\system.mhs

line 114 - connection has no driver!

WARNING:MDT - dcm_0_lock (LOCKED) -

D:\MyData\DESIGNS\V5ML505\testboard\system.mhs line 264 - floating

connection!

Running UPDATE Tcl procedures for OPTION PLATGEN_SYSLEVEL_UPDATE_PROC...

INFO: The Ethernet_MAC core has constraints automatically generated by XPS in implementation/ethernet_mac_wrapper/ethernet_mac_wrapper.ucf.

It can be overridden by constraints placed in the system.ucf file.

ERROR:MDT - platgen failed with errors!"

Solution

This is an error in the ML505 XBD file. It is fixed in EDK9.1i. For 8.2i users, please modify the DCM connections as follows.

BEGIN dcm_module

PARAMETER INSTANCE = dcm_0

PARAMETER HW_VER = 1.00.a

PARAMETER C_CLK0_BUF = TRUE

PARAMETER C_CLKIN_PERIOD = 10.000000

PARAMETER C_CLK_FEEDBACK = 1X

PARAMETER C_DLL_FREQUENCY_MODE = LOW

PARAMETER C_EXT_RESET_HIGH = 1

PORT CLKIN = dcm_clk_s

PORT CLK0 = sys_clk_s

PORT CLKFB = sys_clk_s

PORT RST = net_gnd

PORT LOCKED = dcm_0_lock

END

BEGIN dcm_module

PARAMETER INSTANCE = dcm_1

PARAMETER HW_VER = 1.00.a

PARAMETER C_CLK0_BUF = TRUE

PARAMETER C_CLKIN_PERIOD = 10.000000

PARAMETER C_CLK_FEEDBACK = 1X

PARAMETER C_DLL_FREQUENCY_MODE = LOW

PARAMETER C_EXT_RESET_HIGH = 0

PORT CLKIN = sys_clk_s

PORT CLK0 = ZBT_CLK_OUT_s

PORT CLKFB = ZBT_CLK_FB_s

PORT RST = dcm_0_lock

PORT LOCKED = dcm_1_lock

END