Main

LogiCORE Endpoint PIPE for PCI Express v1.6.1 - 9.1i SP2 Timing Analyzer GUI displays "Unexpected Error in index generation process near line 326 Offending index line is "2 353"

AR# 24952

Search For Another Answer

Topic IP-SystemIO PCI Express PIPE
Last Updated 03/29/2007
Status Active
Description

Keywords: trce, trace, routed.twr, Timing Constraints, TS_RXCLK,TNM_NET_RXCLK

When implementing the S31400A design generated by CORE Generator in 9.1i SP2, the following messages may appear if the timing report is opened in the Timing Analyzer GUI:

Unexpected Error in Index Generation process near line 326 offending index line is "2 353"
Unexpected Error in Index Generation process near line 4074 offending index line is "2 4114"
Unexpected Error in Index Generation process near line 5617 offending index line is "2 5645"

Solution

This is a GUI problem only, as the actual timing report file generated by TRCE does not contain these messages. These can be safely ignored so long as no timing errors are reported in the text timing report.

To work around this, change the implementation file so that the trce command writes out an xml file. The command is:

trce -u -v 100 -xml routed.twx routed.ncd mapped.pcf

Then open the routed.xml file in Timing Analyzer.


 
 