AR# 2875

CPLD: XC9500: Maximum Icc by package type


Keyword: 9500, maximum current, Icc, current

General Description:

The maximum operating current that the XC9500 part can accept

without getting damaged.


Package Max Icc (mA)

------- -------

PC44 400

VQ44 400

PC84 500

PQ100 520

TQ100 550

PQ160 520

HQ208 1100

BG352 1300

These are the maximum Icc's to use as a general rule for each package

type and apply to any XC9500 device in a particular package. These

numbers are calculated based on a maximum device operating temperature

of 160C and an ambient temperature of 75C. Both these numbers are

maximums and should not be exceeded. If the system environment is

cooler than 75C, the max Icc would be greater in that case. At 25C

ambient for example, these numbers may go up by as much as 50%.

AR# 2875
Date Created 08/21/2007
Last Updated 12/15/2012
Status Active