AR# 31159 10.1 EDK, MPMC v4.00.a - Chipselect (CS) asserted too late on Spartan-3 for successful precharge

Keywords: read, bank, rank, deep, activate, ddr

When using the MPMC in a Spartan-3 design in a dual-rank design, the chipselect is asserted too late after a read when switching banks. This could cause an activate failure and data corruption. In simulation, a memory model error similar to the following would occur:
ERROR: Activate Failure. Bank 1 must be Precharged.

This issue is planned to be fixed starting in MPMC v4.03.a and later, to be released in EDK 10.1, Service Pack 3.
AR# 31159
Date Created 06/11/2008
Last Updated 06/11/2008
Status Active
Type
Feed Back