AR# 32627 SPI-4.2 v9.1 - Sink core might not align or go in frame in VCS simulation

The SPI-4.2 v9.1 Sink core might not lock to the data stream or go in frame during VCS simulation due to pulse swallowing.

To avoid this issue, the VCS switch "+transport_int_delays" should be added to the VCS command line as follows:

vcs +no_notifier \

+neg_tchk \

-debug -PP \

+transport_path_delays +pulse_e/0 +pulse_r/0 \

+transport_int_delays +pulse_int_e/0 +pulse_int_r/0 \

-sdf max:pl4_demo_testbench.pl4_wrapper0:../../implement/results/routed.sdf \

pl4_demo_testbench glbl

This command line switch will be added to the SPI-4.2 v9.2 core example design simulation script in the next release.

Revision History

05/04/2009 - Initial Release