Main

MIG v3.1, Spartan-6 MCB - When a MIG MCB project is reloaded using Recustomize (Under Original Settings) display issues occur

AR# 32869

Search For Another Answer

Topic IP-MIG-GUI
Last Updated 06/10/2009
Status Active
Description

Keywords: Spartan 6, Spartan-6, Spratn-6, MCB, MIG, GUI, user interface, arbitration, fpga options, display, blank

When a Spartan-6 single MCB design is reloaded using Recustomize (Under Original Settings), if an additional controller is selected in the memory selection page, some values are shown as blank in the following pages of the GUI:

1. User Interface page
2. Arbitration page
3. FPGA options page for the second controller

Solution

To work around this issue, reopen MIG and create a new MCB design. Currently, MCB projects cannot use the Recustomize (Under Original Settings) option if additional controllers are added to the project. Recustomizing the single controller design will not cause errors.

This GUI display issue will be resolved in MIG 3.2.
 
 