UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 33031

11.x XST - "ERROR:HDLCompiler:852 - "ex_0010.vhd" Line 5: Unit ex_0010 does not have a generic named my_width"

Description

Keywords : Virtex-6, Spartan-6, HDLCompiler:852, generic

The following error occurs in XST when I target Virtex-6 or Spartan-6 devices, but I do not have any issues when targeting older devices. Why?

"ex_0010.vhd" Line 5: Unit ex_0010 does not have a generic named my_width

Solution

This error occurs when the generic name does not match the generic in code.

For older devices, XST ignores the error message, but starting in Virtex-6 and Spartan-6 devices, this will be flagged as an error.

For example:

The generics (-generics) option allows you to redefine generics (VHDL) or parameters (Verilog) values defined in the top-level design block.

In the following examples, width defines the size of the add operation.

File: ex_0010.vhd

Compilation Library: work

library ieee;

use ieee.std_logic_1164.all;

use ieee.numeric_std.all;

entity ex_0010 is -- Note: Error points here

generic (width: integer := 8);

port(a,b : in unsigned (width-1 downto 0);

res : out unsigned (width-1 downto 0));

end ex_0010;

architecture beh of ex_0010 is

begin

res <= a + b;

end beh;

Generics (parameters) can be redefined directly in XST Synthesis options of ISE Project Navigator (see Figure 1).

Figure 1
Figure 1
.

The error occurs due to the difference in generics name. The name should be corrected to resolve this error.

In 11.2, XST introduced a new VHDL/Verilog parser for Virtex-6 and Spartan-6 families. For more information on this change, see (Xilinx Answer 32927).

AR# 33031
Date Created 06/23/2009
Last Updated 12/15/2012
Status Active