11.x XST - "ERROR:HDLCompiler:852 - "ex_0010.vhd" Line 5: Unit ex_0010 does not have a generic named my_width"


Keywords : Virtex-6, Spartan-6, HDLCompiler:852, generic

The following error occurs in XST when I target Virtex-6 or Spartan-6 devices, but I do not have any issues when targeting older devices. Why?

"ex_0010.vhd" Line 5: Unit ex_0010 does not have a generic named my_width


This error occurs when the generic name does not match the generic in code.

For older devices, XST ignores the error message, but starting in Virtex-6 and Spartan-6 devices, this will be flagged as an error.

For example:

The generics (-generics) option allows you to redefine generics (VHDL) or parameters (Verilog) values defined in the top-level design block.

In the following examples, width defines the size of the add operation.

File: ex_0010.vhd

Compilation Library: work

library ieee;

use ieee.std_logic_1164.all;

use ieee.numeric_std.all;

entity ex_0010 is -- Note: Error points here

generic (width: integer := 8);

port(a,b : in unsigned (width-1 downto 0);

res : out unsigned (width-1 downto 0));

end ex_0010;

architecture beh of ex_0010 is


res <= a + b;

end beh;

Generics (parameters) can be redefined directly in XST Synthesis options of ISE Project Navigator (see Figure 1).

Figure 1
Figure 1

The error occurs due to the difference in generics name. The name should be corrected to resolve this error.

In 11.2, XST introduced a new VHDL/Verilog parser for Virtex-6 and Spartan-6 families. For more information on this change, see (Xilinx Answer 32927).