| AR# |
33041 |
| Part |
SW-Chipscope Pro |
| Last Modified |
2009-06-24 00:00:00.0 |
| Status |
Active |
| Keywords |
GTP, GTX, MGT, Logic, Analyzer, JTAG, .cpj |
Description
Keywords: GTP, GTX, MGT, Logic, Analyzer, JTAG, .cpj
After connecting to the board and using the IBERT console, when I attempt to "Save Project" the GUI hangs and the Analyzer process needs to be killed. How do I work around this issue?
Solution
This error occurs if the Programming Cable is closed before the "Save Project" is attempted. When the "Save Project" option is used, the Analyzer polls the core for its current status. If the cable is closed the process hangs.
To work around this problem, ensure the cable is still open and connected when attempting to "Save Project".
This issue is scheduled to be resolved in ChipScope Pro 11.3