AR #33111 - LogiCORE IP Ethernet Statistics v3.x and LogiCORE IP Tri-Mode Ethernet MAC v4.x - Error regarding "No objects found matching..." in the example design timing simulation

Search Answers Database


 

LogiCORE IP Ethernet Statistics v3.x and LogiCORE IP Tri-Mode Ethernet MAC v4.x - Error regarding "No objects found matching..." in the example design timing simulation

AR# 33111
Part IP-DS-Tri-mode Ethernet MAC
Last Modified 2009-09-11 00:00:00.0
Status Active
Keywords host_addr_reg, no objects found matching

Description

Keywords: host_addr_reg, no objects found matching

Occasionally, an error similiar to the following might occur when running the example design timing simulation:

# ** Error: (vish-4014) No objects found matching '/testbench/dut/host_addr_reg'

Solution

These errors can be safely ignored.

This is not a design issue and the result of the simulation is not affected (simulations pass). This error is due to the fact that the script is attempting to display internal design nets in the wave window. However, signal naming post PAR can vary, and in the failing designs these nets have been assigned alternative names.
 
 