AR# 33449

Digital Pre-Distortion (DPD) v2.0, v2.01 - Why do I see poor performance or diagnostics with Over-Drive Protection (ODP) and damped-Newton updates?

Description

Keywords: Pre-distortion, predistortion, power amplifier

Why do I see poor performance or diagnostics with Over-Drive Protection (ODP) and damped-Newton updates?

Solution

There might be poor performance or diagnostics with Over-Drive Protection (ODP) and damped-Newton updates enabled. This could be an issue with software coefficient management. This is fixed in v2.1 by using Least Squares updates when ODP occurs. When using the DCL controller, all DPD updates will be full Least Squares updates until the over-drive condition is cleared. This ensures the fastest method to detect when OD is no longer occurring, and corrects a previous error in the interaction of ODP and dN updates that could cause instability.
AR# 33449
Date Created 09/09/2009
Last Updated 09/16/2009
Status Active
Type General Article