Description

Why do I see a mismatch between the behavioral simulation and the post-implementation gate level simulation results when I use the default GUI Values for Max Clock Per Line and the Max Lines Per Frame?

Solution

This is a known problem that is addressed in the Video Timing Controller v2.1.

To ensure that the behavioral simulation and the post-implementation simulation always match, set the Max Clock Per Line and the Max Lines Per Frame to exactly 4095. 

For a detailed list of LogiCORE IP Video Timing Controller Release Notes and Known Issues, see (Xilinx Answer 32754).