UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 34176

11.4 PlanAhead - EXCEPTION:Xdm:ModelImp.c:994:$Id: (...)- Xdm_Exception::CannotReadFile

Description

When I kick off an implementation run from the PlanAhead tool on a Windows machine, Translate completes, but MAP generates the following error:

"EXCEPTION:Xdm:ModelImp.c:994:$Id: ModelImp.c,v 1.27.50.1 2009/06/16 00:37:40 jdl
   Exp $ - Xdm_Exception::CannotReadFile
   file='../../../../../project_baseline_fp_no_partition.promote/Ximpl_1top_usbE
   ngine1/floorplan_1_prev_mapped.ngm'"

NGDBuild was able to find all the files, so the location of the files is correct. What does this error mean?

Solution

This is a known issue with the PlanAhead tool when run on Windows; the path length limitation on Windows is the cause of the error.

To work around this issue, reduce the path length to the files.

A more descriptive error message is planned for a future release of the PlanAhead tool.

AR# 34176
Date Created 01/20/2010
Last Updated 05/23/2014
Status Archive