AR# 34208

Spartan-6 Aurora 8b/10b - Clock correction sequence not recognized in GTP1 in tile

Description

If anAurora 8b/10b core in Spartan-6 FPGA is implemented in GTP1, it does not recognize the clock correction sequences. This is because the attributes have the wrong values:

CLK_COR_SEQ_*_*_1 = 0111111011

Solution

The attributes must be changed to:
CLK_COR_SEQ_*_*_1 = 0111110111

The settings for GTP0 are correct.

Sequence3 and4(CLK_COR_SEQ_*_3_*/CLK_COR_SEQ_*_4_*)are masked out, so their values do not matter.