AR# 34305

11.x Map - Portability:90 - Command line error: Switch "-t" is excluded or already used

Description


I would like to change the cost table for Map by adding "-t 40" in the "Other Command Line Options"Map property in Project Navigator. However, when I do so, I obtain this error:
ERROR:Portability:90 - Command line error: Switch "-t" is excluded or already used

How can I resolve this issue?

Solution


This error occurs because the cost table switch is already used in ISE's Map command line. Currently, Map does not allow multiple cost table (-t) switches.

To resolve this issue, set the desired starting cost table by changing the value of the "Starting Placer Cost Table" property in the Map process properties.