We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 35169

MIG Virtex-6 DDR2/DDR3 - Determining which calibration stage failed


When phy_init_done does not assert, signifying a calibration failure, it is important to first identify which stage of calibration failed. 

The MIG Virtex-6 DDR2/DDR3 FPGA design goes through the following calibration stages:

This series of calibration debug Answer Records focus on debugging Write Leveling, Read Leveling Stage 1, and Write Calibration / Read Leveling Stage 2.

NOTE: This Answer Record is contained in a series of MIG hardware debug Answer Records and assumes you are running the MIG Example Design with the Debug Port Enabled. It is best to start at the beginning of this recommended hardware debug flow; see (Xilinx Answer 34588)

NOTE: This Answer Record is part of the Xilinx MIG Solution Center (Xilinx Answer 34243) The Xilinx MIG Solution Center is available to address all questions related to MIG. Whether you are starting a new design with MIG or troubleshooting a problem, use the MIG Solution Center to guide you to the right information.


NOTE: These steps assume the Example Design with the Debug Port is running in your hardware. 

If this design is not loaded in your hardware, please go to (Xilinx Answer 34588)

Write Leveling Failures (DDR3 Only)

Signals of Interest:

  • dgb_wrlvl_start = Memory Initialization Completed Successfully and Write Leveling Begins.
  • dbg_wrlvl_done = Write Leveling Completes Successfully.
  • dbg_wrlvl_err = Write Leveling Fails. 
If Write Leveling failed, see (Xilinx Answer 35177)

Read Leveling Stages 1 and 2

NOTE: The calibration algorithm is designed so that Read Leveling Stage 1 never triggers an error. 

An error during Read Leveling would always be seen during Read Leveling Stage 2. 

If a failure is detected during Read Leveling Stage 2, it is crucial to start the debug during Read Leveling Stage 1 and then move to the Read Leveling Stage 2 section. 

For full details on why Stage 1 does not trigger an error, see (Xilinx Answer 35074)

Signals of Interest:


  • 2'b00 = Stage 1 and Stage 2 did not finish.
  • 2'b01 = Stage 1is complete, stage 2 has not finished.
  • 2'b11 = Read Leveling completed successfully.

dbg_rdlvl_err = Indicates when an error occurs during Read Leveling Stage 2 (see above note on Stage 1 failures).

For information on Read Leveling Stage 1 Debug, see (Xilinx Answer 35183)

For information on Read Leveling Stage 2 Debug, see (Xilinx Answer 35193)

For generation information on usage of the Debug Port, see (Xilinx Answer 35206)