UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 35293

12.2 CORE Generator - 'Project Processes' fail when the process does not apply to all IP cores

Description

There are a number of CORE Generator processes that operate on all IP Cores in a CORE Generator project. 

Examples of these processes are Regenerate All IP and Update All IP.

In CORE Generator 12.1, if one of these "Project Processes" encounters an IP core that they do not apply to (e.g. A version of a core that cannot be regenerated in the current software version), the process fails instead of skipping or flagging the individual IP core.

Solution


To work around this issue, a user will need to either remove the incompatible IP from the CORE Generator project directory or run the equivalent individual process on each IP core.
 
This issue has been resolved in ISE DS 12.3.
AR# 35293
Date Created 08/25/2010
Last Updated 05/23/2014
Status Archive
Type Known Issues
Tools
  • ISE Design Suite - 12.1
  • ISE Design Suite - 12.2