UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 35613

12.1 RTL/Technology Viewer - Exporting an RTL/Technology color scheme causes ISE crash on Linux

Description

While a schematic or RTL/Technology view is open, if a userexports an RTL/Technologycolor scheme, Project Navigator closes.

To reproduce:

  1. Open a schematic page in Schematic Editor
  2. Run View RTL Schematic, or run View Technology Schematic.
  3. Select Edit -> Preferences
  4. In the Category pane select RTL/Technology Viewer ->Color Scheme.
  5. Press Export
  6. Type a file name and press Save.

Project Navigator closes and results in a stacktrace error that begins with:

*** glibc detected *** /ISE_install_directory/bin/lin64/_pn: corrupted double-linked list: 0x00000000214698a0 *

Solution

This issue seems to occur when usingLinux and KDE, and is occurring in the low level glibc code version 2.3.4-2.26.

Glibc-2.3.4-2.41 does not exhibit this problem.

If you experience this error, please report it to Xilinx Technical Support.

AR# 35613
Date Created 05/10/2010
Last Updated 12/15/2012
Status Active
Type General Article
Tools
  • ISE Design Suite - 11.1
  • ISE Design Suite - 12.1