M1.4 PAR, TRCE, Timing - How to invoke the "KPATHS" timing algorithm.

Solution

The KPATHS timing algoritm is enabled by setting the
following environment variable:

setenv XILINX_GRAPHIMP KPATHS (work stations)
set XILINX_GRAPHIMP = KPATHS (PCs)

When the KPATHS algorithm is being used, PAR and TRCE
will output the following message:

"Invoking connection based timing analysis"