AR# 38375

SmartXplorer - When does SmartXplorer begin running variability passes?

Description

Even though I have enough resources (processors) SmartXplorer does not start running variability passes as soon as the first strategy completes. What needs to occur before SmartXplorer begins running these passes?

Solution

SmartXplorer will not start running variability passes until 50% of the base strategies have completed. At that point variability passes will begin on the current best strategy. If a new best strategy is identified, then the variability passes will be switched over to that strategy.