AR# 40118

12.3 EDK - ERROR:EDK - xps_intc_ (xps_intc) - Interrupt Port - 'int_0' cannot be without Sensitivity

Description

Changing the interrupt controller version resulted in the following error message:

ERROR:EDK - xps_intc_0 (xps_intc) - Interrupt Port - 'int_0' cannot be
    without Sensitivity
    (SENSITIVITY=EDGE_RISING|EDGE_FALLING|LEVEL_LOW|LEVEL_HIGH)

Solution

The xps_intc now requires that Sensitivity be set for the interrupt signal tied to the core. 

In order to resolve this issue, set a Sensitivity value for the interrupt signal in the MHS.